Manufacturer reference specifications: LiCELL AH002
- AVD agent volume: 2 L (.53 gal)
- Manufacturer battery capability reference: ≤ 200 Wh
- Discharge time: 50 seconds
- Discharge range: 2.0 m (6.6 ft)
- Includes a standard wall mount. Heavy-duty marine and vehicle brackets are optional.
View the AH-series datasheet · View the AVD Safety Data Sheet
LiCELL - 2L AVD - Lithium Battery Fire Extinguisher
Product Description:
A portable fire extinguisher with AVD (Aqueous Vermiculite Dispersion) agent, designed as supplemental protection for lithium battery fire risks. Intended for lithium-ion and lithium-polymer battery fire risk areas, as well as electrical and Class A fire risks. Environmentally friendly with no GWP (Global Warming Potential), non-toxic to people, animals, and plants.
Lithium battery fires are fast and dangerous due to “thermal runaway,” triggered by cell failure from damage, defect, short circuit, overcharging, or overheating. LiCELL™ extinguishers with AVD encapsulate the fire source, creating a non-flammable oxygen barrier and providing a cooling effect to help address thermal runaway.
Lithium battery failure can be caused by:
- Physical impact or penetration
- Overheating
- Short circuits
- Internal cell failure
- Manufacturing defects
As lithium batteries become more common in boats, workshops, warehouses, data centers, tools, e-bikes, and portable power systems, supplemental lithium battery fire response planning is increasingly important.
The consequences of lithium battery fires are severe, so taking proper supplemental precautions is important.
LiCell AVD Extinguisher Video
Watch a controlled scooter lithium battery fire demonstration showing how quickly these fires can escalate and how LiCell AVD is applied as supplemental protection. For battery rooms, warehouses, workshops, data centers, e-waste facilities, marine systems, and industrial lithium battery risks, compare extinguishers by usable AVD agent volume — not just canister price.
Controlled lithium battery fire demonstration using a LiCell AVD extinguisher. Always evacuate, call emergency services, and only use an extinguisher if it is safe to do so.
📖 Need help comparing LiCell AVD extinguishers? Read the buying guide.
Frequently Asked Questions
Where are LiCell AVD extinguishers commonly used?
LiCell AVD extinguishers may be considered as supplemental portable protection for lithium-ion and lithium-polymer battery risks in industrial, commercial, government, marine, and technical environments. Common applications include battery rooms, data centers, UPS battery backup areas, server rooms, e-waste and recycling facilities, warehouses, workshops, aviation and aerospace support areas, forestry and government field operations, lithium battery storage areas, and marine vessels.
Why does AVD agent volume matter?
AVD extinguishers are not all equal. A lower-priced canister may contain less usable AVD agent, reducing practical coverage and requiring additional units. When comparing lithium battery fire extinguishers, review agent volume, extinguisher size, intended application, and total cost of protection.
Is the cheapest lithium battery extinguisher the best value?
Not always. A cheaper unit with less AVD agent may cost less upfront but require more units for the same practical response. For battery rooms, data centers, warehouses, e-waste facilities, workshops, aviation support, government operations, marine vessels, and industrial lithium battery risks, the better measure is cost per usable litre of AVD agent.
Which lithium battery types is LiCell AVD intended for?
LiCell AVD extinguishers are intended for lithium-ion and lithium-polymer battery fire risks, as well as electrical and Class A fires. If you are dealing with lithium-metal batteries, unusual battery chemistries, or a large engineered battery system, consult your fire protection professional, insurer, or authority having jurisdiction.
Is LiCell AVD suitable for LiFePO4, LFP, and lithium-polymer batteries?
LiCell AVD extinguishers are intended for lithium battery fire risks, including lithium-ion and lithium-polymer batteries. LiFePO4, also called lithium iron phosphate or LFP, is a common lithium-ion battery chemistry used in marine batteries, solar storage, RV systems, portable power stations, industrial equipment, and energy storage applications.
If your battery is a lithium-ion chemistry such as LiFePO4/LFP, LiCell AVD may be considered as a supplemental portable response option when used as directed. For lithium-metal batteries, unusual chemistries, or large engineered battery systems, consult the battery manufacturer, fire protection professional, insurer, or authority having jurisdiction.
Can LiCell AVD extinguishers help with thermal runaway?
LiCell AVD is designed to address lithium battery thermal runaway by cooling the fire source and forming a non-flammable barrier when applied as directed. Thermal runaway can be severe, fast-moving, and may involve re-ignition risk, so these extinguishers should be treated as supplemental protection, not a replacement for evacuation, emergency response, code-required extinguishers, engineered suppression systems, or facility fire procedures.
Why do lithium battery fires create environmental and cleanup concerns?
Lithium-ion battery fires can involve extreme heat, toxic smoke, venting gases, re-ignition risk, and contaminated debris. This is especially important for marine vessels, forestry operations, e-waste facilities, warehouses, data centers, and industrial sites where a battery fire can affect people, equipment, air quality, water, soil, or surrounding property. LiCell AVD extinguishers are intended as a supplemental portable response option and should be used alongside evacuation procedures, emergency response plans, proper battery storage, and any required cleanup or disposal process.
Are LiCell extinguishers shipped through dangerous-goods shipping channels?
Yes. LiCell extinguishers ship through dangerous-goods shipping channels. Preparation and documentation are required before shipment, which is why these products do not normally ship the same day.
Can LiCell AVD extinguishers be shipped to California?
California has specific requirements for portable fire extinguishers. LiCell AVD extinguishers are sold for supplemental use and California orders can only be processed under limited circumstances. California customers should contact us before ordering.
Are LiCell AVD extinguishers a replacement for required fire extinguishers?
No. LiCell AVD extinguishers should be considered supplemental lithium battery fire protection unless your fire marshal, fire protection engineer, insurer, or authority having jurisdiction confirms otherwise. They should not be treated as a replacement for code-required extinguishers, sprinkler systems, battery-room fire protection, or facility emergency procedures.
Customers Also Buy
Many customers pair this extinguisher with a matching LiCell mounting bracket for secure installation on vessels, walls, vehicles, or equipment racks.
➡ LiCell Mounting Metal Bracket 2L — designed to fit the AH002 2L extinguisher
Also available: ½L bracket | 1L bracket | 4L bracket | 6L–9L bracket
SHIPPING STATEMENT
CALIFORNIA ADDRESSES click here BEFORE ordering
Dangerous-goods preparation is required before shipping. Please allow approximately 5–7 business days for preparation before shipment. Transit time begins once the order has been released to the carrier. For larger quantities, international shipments, Alaska, Hawaii, or California addresses, please contact us before ordering.
CALIFORNIA: (see link above)
We currently sell to California customers in six circumstances outlined below:
• Extinguishers used for testing purposes.
• Customers with their own firefighting function/group/department
• Customers with approval from the local fire department or fire marshal
• U.S. Government location (e.g., DOD, USCG, FAA, USDA) located in CA
• Marine vessels temporarily docked in California with a home port and billing address outside CA
• California customers with an order ship-to address outside CA
Please note, if you order these from California in error, we will charge a 5% restocking fee to refund your order (as that is what we are charged)
Share

We recently purchased the LiCell AH002 2L AVD Lithium Battery Fire Extinguisher and have been very pleased with the overall experience. The unit arrived quickly, on time, and exactly as described.
While we have not had the need to use the extinguisher in an actual emergency situation, it appears to be well-built and is exactly what we were looking for to enhance our lithium battery fire safety preparedness. The compact size, clear labeling, and specialized AVD technology made it a great fit for our facility's needs.
The ordering and delivery process was smooth, and the product arrived in excellent condition. Based on our purchasing experience, we would recommend this extinguisher to organizations looking to improve their lithium-ion battery fire safety measures.
It’s finally here thank you guys so much
Safety is my number one priority. I appreciate your awesome service swift quick and easy to order. Definitely looking forward to grab a couple more.
Again, thank you 🙏
LITHIUM Battery Fire Extinguisher was fine. However, the time from order to delivery was much too long. 2/23/2025 to 3/20/2025 about a month.
We’ve bought two of these li-ion battery fire extinguishers to raffle for recycling centers and transfer stations. Anyone working with solid waste should have one of these in their facility!